Daikin air conditioning repairs in London.


All of engineers are very experienced at carrying out Daikin repairs anywhere in London. Our capital city is covered by our fleet of service vehicles operating throughout the capital serving customers from all areas domestic, commercial and industrial.

We have been carrying out Daikin Repairs for over a decade throughout London and all of its boroughs.

We have carried out work for some of the biggest retailers in the UK, Greggs, GAP, Percy Ingles to name but a few, these customers have relied on delta T services to keep their stores operational with as little down time and interruption to business as possible, we believe we can do the same for you !

No matter what Daikin equipment you have if it can be repaired then we can carry out these works, we have access to a vast array of spare parts off the shelf with very short delivery times.

All of our service vehicles carry a stock of refrigerants and basic spares for the more common failures, our engineers can often affect a Daikin repair there and then and have your equipment up and running on the day.

common faults


Frozen Coil One of the most common problems is a frozen indoor coil, this can be caused by a variety of things but is often as simple as very dirty filters that have not been cleaned for a long time, these restrict the air flow across the coil and when icing occurs can become apparent by water dripping from the unit or running down the wall in the case of wall mounted systems. This can also be caused by a low refrigerant level within the system often caused by a leak from either fractured pipe work or a mechanical fitting that has vibrated loose.

Condenser not working

Dependant on the location of the external unit it is a common fault for someone to have switched off the mains power isolator, always best to check this item first as it can save you money, if this is the case and it is a common occurrence we can fit security cages to your units. These symptoms may also be caused by faulty contactors, tripped MCB on the mains fuse board. The outside fan is responsible for transferring the heat from inside the building to the outside air,  If the fan on the outside unit doesn’t run, proper heat transfer is not taking place and the air conditioning compressor may overheat and trip the safety overload. Worse yet, it may cause internal damage to the compressor.

Faulty wiring

It is not uncommon to have mice or rats chew through cabling be it mains power or communication cables running between the indoor and outdoor units, connections can over a long period of time become loose if not checked periodically, the system has moving parts which can generate vibration to terminals and casework, proper maintenance removes this type of problem almost completely.
Water ingress can also play havoc with the system electrics but should be referred to a qualified person to resolve.

Refrigerant loss
Refrigerant is the chemical that cools or heats the air. Low refrigerant may indicate a leak or problem within the refrigerant system.  If your air conditioning system needs to be recharged with refrigerant, typically that means there is a leak.  All refrigerant leaks should be located and repaired immediately under the F-Gas regulations.

delta T Services are a Daikin D1 approved company; make us your first choice Daikin repairs in London.

All Daikin parts supplied by us come with a standard one year manufacturers warranty as standard.

If you would like someone to talk to about your requirements for a Daikininstallation either in London then Call our friendly help desk now or e-mail us via the request a quotation page with your details and we will contact you shortly.